Week one: time the work you already do
Pick one service and two common visit types, then appoint a clinical lead and a backup with authority to pause the pilot. Over five working days, record how long participating clinicians spend documenting comparable visits. Count work outside the EHR and after hours, and separate hands-on work from the elapsed time until signature. Get privacy and security approval for the proposed workflow, recording, storage, and staff access before any real use. If these checks are incomplete, keep the exercise synthetic.
Agree on how clinicians will explain the tool, offer the usual documentation workflow when it is declined, and verify every note before signing. AMA ethics training emphasizes disclosure, consent, and manual verification. Rehearse pausing capture and dropping back to ordinary documentation with mock encounters; do not let testing introduce patient data into an unapproved workspace.
Week two: measure corrections, not just first drafts
Keep the clinicians and visit types comparable. Record the number of eligible visits, attempted uses, finished drafts, failures, and fallbacks. Time setup, draft review, EHR edits, and sign-off. The UCLA randomized trial’s EHR metric missed editing in the vendor interface. If your stopwatch starts when the draft arrives and stops before the final fixes, your pilot can miss work for the same reason.
- Write a material-correction definition in advance. Examples include fixing wrong attribution, removing an unsupported fact, and restoring an omitted instruction already agreed with the clinician.
- Set a local threshold and a separate stop rule. For a fictional scorecard, material corrections in more than two of 20 reviewed drafts could mean no expansion; one serious near miss, wrong-chart transfer, or unconsented recording would trigger an immediate pause. These are illustrative thresholds, not safety benchmarks.
- Rehearse the fallback. In a mock visit, the participant withdraws permission halfway through. Confirm the clinician can stop capture, carry on with standard notes, and report the exception under local policy.
Make the decision on day ten
Have the clinical lead review baseline and pilot time, the correction tally, how often the tool was actually used, and whether privacy or workflow exceptions were closed. Pause if the stop rule fired. Extend at the same size if the sample is too small or training still dominates timing. If the result meets the agreed criteria, authorize only the next bounded evaluation, with an owner and review date. Two weeks can reveal workflow friction and obvious failure modes; it cannot demonstrate clinical safety, return on investment, or suitability across specialties.
If the team cannot explain who owned the extra work, do not call the time difference a savings.
Sources and further reading
- AMA Ed Hub: Ethical decision simulator for ambient AI scribes
- NEJM AI: Randomized ambient scribe trial and EHR timing limitation
- JAMA: Multisite cohort and variation in use
The example thresholds and mock visit are fictional. No product or live workflow was tested for this article.