Sample the notes most likely to teach you something
Appoint a quality lead and a clinician for adjudication. Start with a weekly sample while the workflow is new, then set the ongoing cadence based on incidents, usage and model changes. Take a small random sample across clinicians and visit types, plus a separate targeted sample after a template change or complaint. Track how many drafts each group represents. A finding in targeted cases can reveal a failure pattern, but the targeted sample does not estimate how often it occurs across the practice.
Review only within the approved quality workflow and use only source material the reviewer is permitted to access. Compare the draft and signed version where both are available, then verify disputed facts using a permitted source or the clinician’s account. If the source is unavailable, record the limitation rather than guessing or creating a new audio archive. AMA training calls for manual verification of AI documentation; a spot-check does not replace the signing clinician’s review.
Look for what an edit count misses
A JMIR study used a controlled simulation to categorize omissions, additions, incorrect output, and misplaced text; omissions were the most common type it observed. That is a reason to look for absent information, not a population-wide error estimate. A randomized UCLA trial also reported occasional inaccuracies and called for ongoing vigilance. Use categories your reviewers can apply consistently.
- Missing: A detail present in the permitted source is absent from the draft. A reviewer cannot spot this by reading the draft alone.
- Unsupported or wrong: The draft invents a statement, reverses its meaning, or attributes it to the wrong speaker. Style edits alone should not count as substantive corrections.
- Misplaced: The information is real but appears where a downstream reader could mistake its role. Track the section, software version, and whether the error persisted after signing.
Route the finding before it becomes a pattern
In a fictional review, a family member describes their own experience and the draft assigns it to the patient. The clinician corrects it before signing. Record it as wrong attribution caught before signing, not as an error in the final chart. If a similar error is found after signing, follow the record-correction and incident process; do not silently overwrite the record. For repeated defects in one template or workflow, have the quality lead assign a fix, decide whether to pause that use, and review a fresh sample before re-enabling. Bring counts, sample sizes, version, and action owner to the next quality meeting.
Reviewers should report what the evidence shows and flag unresolved attribution rather than counting every difference between draft and final as an error.
Sources and further reading
- JMIR: Original simulated study of scribe error categories
- NEJM AI: Randomized trial and clinician-reported inaccuracies
- AMA Ed Hub: Ambient scribe ethics and manual verification
The audit example is fictional. Have local clinical, privacy, and quality leads review the checklist before using it.