SMART on FHIR vs. a custom EHR interface: what to test first

A standards-based launch can simplify how an app opens and gets permission. Use the same fictional encounter to compare what each option actually reads, writes and leaves for your team to support.

Two blue network cables with clear connectors on a gray surface.

AI-generated editorial illustration; no patient records are depicted.

Healthcare Tech Source content and product recommendations are editorially independent. We may make money when you click on links to our partners. Learn More

Start with the job, not the interface

Suppose a clinician launches a referral app from a chart, reviews an encounter and sends a draft referral back. That is three separate requirements: open in the right context, read the right information and return something usable. Before either vendor gives a demo, decide which of those steps has to happen inside the EHR and which could happen in a separate interface.

HL7’s SMART App Launch guide describes how apps can receive context, such as the selected patient, and request access with defined permissions. A custom interface is a connection designed for a specific workflow or deployment. It might still use FHIR for some exchanges. The choice is not necessarily one standard or the other: a SMART launch could coexist with a separate write-back path.

Run the same acceptance test on both options

Use a nonproduction environment and two fictional patients with similar names. Give one an open encounter and the other a closed encounter. Use the same synthetic referral, the same roles and the same pass criteria for both options. Have your own staff operate the workflow; a vendor clicking through a prepared scenario is not the same test.

  • Launch and context: Open each chart and verify that the app selects the expected patient and encounter. Switch charts and check that the app does not silently retain the prior patient’s context.
  • Permissions: Compare an authorized clinician with a deliberately limited test role. Confirm that expected reads work, unavailable records remain unavailable and the user sees a useful explanation when access is denied.
  • Write-back: Ask the vendor to specify the actual route, target field and document status. Submit a fictional draft, repeat the action and verify where it landed, who can see it, whether a duplicate was created and who must sign.
  • Recovery: Rehearse a simulated failed transfer. Verify who sees the failure, where it is logged, who owns retry or manual recovery and how the receiving team can tell that the draft is still outstanding.

Put the results in the agreement

ASTP/ONC’s standardized API test method covers specified certification criteria for a health IT module. It is useful evidence, but not proof that your installed EHR version, configured roles or referral write-back will behave as expected. Ask the vendor to name the module, version, supported interfaces and any separately licensed components.

Score each test as observed, conditional or unsupported. If both approaches pass, compare the support owner, upgrade revalidation and recovery effort. If only a custom write-back meets your clinical requirements, budget for that dependency explicitly rather than assuming the SMART launch covers it. Keep the acceptance log with the contract so the team can repeat the test after a major update.

Sources and further reading

Illustrative procurement test using synthetic data only. No products were tested or certified by Healthcare Tech Source.